理光MPC8002一直报“关闭抽屉单元”
症状故障:Always Alam“Please Close the Drawer Unit” 一直报“关闭抽屉单元”原因1. Drawer Knob Sensor、Drawer Set Sensor、Drawer Lock Sensor、Drawer Lock Moter defective。抽屉旋转传感器、抽屉放置传感器、抽屉锁定传感器、抽屉锁定电机故障。2. DUB、PFB、IOB defective。DUB、PFB、IOB故障。3. Communication (Input/Output to PCB) defective。输入\输出设备至PCB之间连接故障。维修过程
1. Using SP5803 to detected Drawer Knob Sensor、Drawer Set Sensor、Drawer Lock Sensor,they were normal;使用SP5803测试抽屉旋转传感器、抽屉放置传感器、抽屉锁定传感器、抽屉锁定电机都正常;2. Using SP5804、1040 to detected Drawer Lock Moter, its normal also;使用SP5804、1040测试抽屉锁定电机也正常;3. Repalced DUB、PFB、IOB one by one,Failure still;依次更换DUB、PFB、IOB后,故障未排除;4. I found out Drawer Unit Set Switch1\2 on the framework from the PtoP Diagram,but they were not found in SP5803;根据PtoP资料发现机架上还有抽屉单元放置1、2开关与故障相关,但在SP5803列表中未找到该测试项目;
5. Measurement connection was normal(Drawer Unit Set Switch1\2 to ECO);确认抽屉单元放置1、2开关至ECO连接线束正常;6. Confirmation was bad contact by multimeter(Drawer Unit Set Switch1\2)。使用万用表确认抽屉单元放置1、2开关断路造成该故障。**** Hidden Message ***** 学习学习学习 啦咯啦咯啦咯啦咯啦咯啦 fvgvbbbgg
页:
[1]