西湖看花 发表于 2024-3-18 10:02:00

理光Pro8200 开机报代码SC670-00 SC590-09 SC544-02 SC665-04

症状: 1,机器开机后随意报 SC670-00 SC590-09 SC544-02 SC665- 04 等代码(如图)
https://www.073868.com/data/attachment/forum/202308/19/193001yzeo8hc6i2e45u8h.jpg.thumb.jpg
https://www.073868.com/data/attachment/forum/202308/19/193001untobohmq2qsbj71.jpg.thumb.jpg
https://www.073868.com/data/attachment/forum/202308/19/193001z4k03miz0e1rk1vl.jpg.thumb.jpg
https://www.073868.com/data/attachment/forum/202308/19/193002ld51nnfzpdgbnss1.jpg.thumb.jpg

原因: 从代码字面意思来看都与 IOB 有关,其实正真原因是 BCU 和 CNB 直接无法建立通讯导致数据无法反馈给 IOB(如图),导致乱 跳代码.https://www.073868.com/data/attachment/forum/202308/19/193002vzosj7377x72orv3.jpg.thumb.jpg
解决方案:
1、检查 BCU 和 CNB 连接排线(如图)
https://www.073868.com/data/attachment/forum/202308/19/193045vzauahyynqererwy.jpg.thumb.jpg
2、检查此排线的金属片是否氧化或者损坏,如果氧化则用橡皮小心 的擦一下(如图)
https://www.073868.com/data/attachment/forum/202308/19/193053b8cco8m8178im8o2.jpg.thumb.jpg https://www.073868.com/data/attachment/forum/202308/19/193053wc02ju9j9pj3pxzs.jpg.thumb.jpg https://www.073868.com/data/attachment/forum/202308/19/193053wmdaa0h0dzdd0dab.jpg.thumb.jpg
3、如果还是不行,更换此排线。 总结:此类故障多少会出现在客户环境差,潮湿或客户用加湿器的 水是自来水,导致水碱太大,使其导致一些金属接触点氧化。
备注:排线编号:D1495387

383858801 发表于 2024-6-12 18:11:08

谢谢分享

一剑针情 发表于 2024-8-9 01:19:53

{:2_25:}{:2_25:}{:2_26:}{:2_25:}{:2_25:}

sffkk 发表于 2024-8-30 20:37:47

电源板报了吧
页: [1]