施乐Docu Print 3205d,3505d,4405d英文维修手册
Cause: 124-341
One of the CRUM destination values held in th 「ee locations does not match (Data stored in the MCU Board does not match).
124-351
One of the CRUM OEM destinations held in three locations does not match (Data stored in the MCU Board does not match).
124-361
One of the CRUM Enable/Disable settings held in three locations does not match (Data stored in the MCU Board does not match).
124-381
One of the CRUM destination valu侄s held in three locations does not match (Data stored in the MCU Board does not match).
124-391
One of the CRUM OEM destinations held in three locations does not match (Data stored in the MCU Board does not match).
1st action (Check by User)
Turn the power off and on to check if the erro「recurs . 2nd action (Check by Engineer)
Then, proceed to the t「oubleshooting following the table given below