施乐Apeos C8180_C7580_C6580英文维修手册1.5版+维修数据
施乐维修手册或者文档打开统一密码
密码:tdlcsdec04
Chain
No | Link
No | Component名 | Description | IN | OUT | Time
Out | Multiple Output Prohibited Items | Cyclic
Operation | Module Name |
Chain
No | Link
No |
094 | 001 | 1st BTR Voltage Y | Output the Polar Voltage of Constant Current (+) for the 1st BTR Y.
The output value is the NVM (Primary Transfer Output Fixed Value #1 [0.1 μA]). | | ○ | - | | | × | X'fer |
094 | 002 | 1st BTR Voltage M | Output the Polar Voltage of Constant Current (+) for the 1st BTR Y.
The output value is the NVM (Primary Transfer Output Fixed Value #2 [0.1 μA]). | | ○ | - | | | × | X'fer |
094 | 003 | 1st BTR Voltage C | Output the Polar Voltage of Constant Current (+) for the 1st BTR Y.
The output value is the NVM (Primary Transfer Output Fixed Value #3 [0.1 μA]). | | ○ | - | | | × | X'fer |
094 | 004 | 1st BTR Voltage K | Output the Polar Voltage of Constant Current (+) for the 1st BTR Y.
The output value is the NVM (Primary Transfer Output Fixed Value #4 [0.1 μA]). | | ○ | - | | | × | X'fer |
094 | 005 | 2nd BTB CLN Voltage | Output the Polar Voltage of Constant Voltage (+) for the 2nd BTR.
The output value is the NVM ("Reverse Bias Output Value During Diag [+10V]"). | | ○ | - | 094 | 006
007 | × | X'fer |
094 | 006 | 2nd BTB Voltage | Output the Polar Voltage of Constant Voltage (-) for the 2nd BTR.
For the output value, NVM ("Secondary Transfer Fixed Output Value (Side1) [-10V]") is output. | | ○ | - | 094 | 005
007 | × | X'fer |
094 | 007 | 2nd BTB Current | Output the Polar Current of Constant Current (-) for the 2nd BTR.
Output NVM(Fixed Value for Diag) for Output Value. | | ○ | - | 094 | 005
006 | × | X'fer |
094 | 008 | IBT Mot reverse rotation | IBT Motor Reverse Rotation Operation
Reverse rotates and stops only for the NVM specified time | | ○ | 800ms | 042
042
042
042
042
042
042
042
042
042
042
042
042
042
042
042
042
042
| 025
026
027
028
029
030
037
038
039
040
041
042
043
044
045
046
047
048
| × | X'fer |